Post Offer Free
Xi'an Sitan Instruments Co., Ltd  

Gold Index: 1933

You are here: home  > Cased Hole Logging Tools  > Electromagnetic Defect System (EMDS/MDT)

Electromagnetic Defect System (EMDS/MDT) 

Payment Terms: T/T,T/T 
Place of Origin: Shaanxi, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: 12.75 in
Production Capacity: 1000
Delivery Date: 1 month
Maximum temperature: 177
OD: 43mm
Means of Transport: Ocean,Land,Air
Packing: wooden
Brand Name: Sitan
Maximum pressure: 103.4MPa

The EMDS tool detects the tubing or casing thickness, corrosion, deformation, cracks etc.in tubing, indicating downhole string structure, tool locatio

The EMDS tool detects the tubing or casing thickness, corrosion, deformation, cracks etc.in tubing, indicating downhole string structure, tool location and detecting the ferromagnetic material (such as casing centralizers, surface casing, etc.) outside casing.

Due to the unique structure and measurement principle, logging can be performed in the course of normal production of oil/water/gas wells, reducing operating cost in inspection and increasing efficiency, giving the extent of damage of casing in time.

Features

  • Full function: The damage and thickness of tubing and casing, temperature, gamma, etc. can be measured in just one trip.

  • Easy maintenance: Simple mechanical structure, easy disassembly and easy maintenance. 

  • Various operating modes: Cascade connection, connection with MFC, etc.or independent operating.

Maximum temperature

177℃

Maximum pressure

103.4MPa(15000psi)

OD

43mm(1.69in)

length

2300mm

weight

10Kg

Operating voltage

90±8V/18V

Operating currency

(135±5)mA/(550±50)mA

Maximum logging speed

400m/h

Measuring range of pipe diameter and thickness

Measuring range of pipe diameter

62~324mm(2.44in~12.75 in)

pipe thickness

3~12mm(0.11in~12.75 in)

Total maximum thickness of double pipes

25mm(0.98in)

Measuring error of single pipe thickness

0.5mm(0.019in)

Measuring error of casing through tubing

1.5mm(0.059in)

Minimum length of longitudinal damage

50mm(1.96in) 2.5" single pipe  70mm(2.75in)5.5" single pipe 150mm(5.90in.)5.5" casing through tubing

Minimum length of transversal damage

1/4 circumference

Minimum diameter hole damage

30mm(1.18in.)

Measuring range of Gamma

(0~2000)cps

Gamma sensitivity

1cps

Measuring range of temperature

-40℃~177℃

Temperature resolution

0.1℃

Temperature accuracy 

±1℃

Housing material

Tc4

Come from: en.sitan-china.com ,For more information, please refer to:en.sitan-china.com/products/oilfield-logging-service/Well-Integrity-Monitoring/Emds-mdt.html

bigPhoto
 Mr. hanrui

Tel: 86-29-88814516
Mobile: 180 4902 6960
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Xi'an Sitan Instruments Co., Ltd [China (Mainland)]


Business Type:Manufacturer, Service
City: Xi'an
Province/State: Shaanxi
Country/Region: China (Mainland)

You May Like: